MCNext™ SYBR® Fast qPCR Library Quantification Kit

$452.07

A unique kit directly measures library concentration, provides a fast and reliable solution for cluster density estimation for NGS. This is achieved by providing a constructed library rather than a single DNA fragment as the control standard with known cluster generation density on Illumina® sequencing platforms.
SKU OPTIONS PriceQuantity
IQPQ-UN No ROX added, 500 reactions $452.07
spinner
IQPQ-RR Regular ROX, 500 reactions $452.07
spinner
IQPQ-LR Low ROX, 500 reactions $452.07
spinner

Description

Rox Reference Dye Instrument
No Rox BioRad iCycler MiniOpticon, Opticon 2, Chromo 4, iQ5; Roche LightCycler 480; MJ Research DNA Engine Opticon 2, Chromo 4; Corbett Rotogene 3000, 6000.
Low Rox ABI® 7500 qPCR Systems, ViiA™ 7, QuantStudio™ 12K Flex, Agilent Mx3000P™ Mx3005P™ and Mx4000™.
Regular Rox ABI® PRISM® 7000, 7700, 7900HT, ABI® 7300 qPCR Systems, GeneAmp® 5700, StepOne™, and the StepOnePlus™.

Description:
Accurate quantification of NGS DNA libraries is critical to ensure efficient data generation and high quality reads. Quantitative Polymerase Chain Reaction (qPCR) is a highly sensitive and accurate approach for quantifying a NGS library and uses a minimal amount of material compared to other quantification methods.  The qPCR quantification tracks library concentrations as a function of PCR cycle number in order to derive a quantitative estimate of the initial template concentration based on the known DNA concentration as control or standard. Thus, the control template should be as similar as possible to the libraries for quantification, in terms of template size, GC content and library type. It is also very important that a constant quantity of the control template is available, as for each round of library quantification determines the cluster generation efficiency, in turn to adjust the loading amount of constructed libraries for the sequencing, even slight variation of the standard leads to fluctuation of cluster density, either compromise the data quality or waste the sequencing capacity.

The MCNext™ SYBR® Fast qPCR Library Quantification Kit provides a fast and reliable solution to determine the library concentration with a direct estimate cluster density. This direct measurement method significantly saves time and resources comparing with other qPCR library quantification kits on the market. This is achieved by providing a constructed library rather than a single DNA fragment as a control standard with known cluster generation density on Illumina® sequencing platforms.

The MCNext™ SYBR® Fast qPCR Library Quantification Kit utilizes MCLAB’s high performance fast PCR enzyme by a Phi X genome based Library Standards (for seven 10-fold dilutions) with an average size of 570 bp, providing quick and accurate quantification with 0.0001 – 100 pM dynamic range in 60 min. Based on the quantification, the result could be directly converted to cluster numbers for loading volume references.

The MCNext™ SYBR® Fast qPCR Library Quantification Kit is a rapid solution for your library construction QC to add value to your workflow and increase confidence in your results. The proprietary Phi X Library Standards consist of a group of Illumina® sequencing  adapter-ligated DNA fragments derived from the Phi X genome with well-characterized sequence and well-balanced GC content (50%). To use this library as a control for libraries constructed for sequencing on Illumina® sequencing platforms is far superior than a single DNA fragment as control standard used by other qPCR quantification kits on the current market. It can be rapidly interpolated for the estimating cluster density and serves as a quantification baseline for sample libraries without the need to have another sequencing run for a cluster density measurement purpose. It is an excellent control with measured cluster generation conversion parameter to examine the library quality and quantity, allows you to quickly determine if an error is related to the sample preparation before a high-cost sequencing run. Quantification is fast, direct and accurate by extrapolation against the standard curve generated using the seven 10-fold Library Standards dilutions, followed by a simple cluster number conversion.

The MCNext™ SYBR® Fast qPCR Library Quantification Kit is available in 3 types (Regular ROX, Low ROX and Universal) based on the internal reference dye preferences of the PCR thermocyclers. The packages include ready-to-use 2X Master Mix, 10X Primer Mix and Phi X Library Standards.

Features

The MCNext™ SYBR® Fast qPCR Library Quantification Kit provides researchers with an accurate and sensitive method for quantifying NGS libraries.

  • Direct quantify library cluster density before loading the samples
  • Accurate library quantification using Phi X genome based Library Standards
  • Consistent library quantification across a broad range of samples
  • High performance and fast PCR enzyme, high sensitivity and rapid detection, simplified steps
  • Adaptable to high-throughput library quantification for larger barcoding applications
  • Tailored for libraries constructed by Illumina® TrueSeq and Nextera workflows

Convenient packages for all types of real time PCR platforms

Kit Components:

MCNext™ SYBR®  Fast qPCR Library Quantification Kit (Universal) (IQPQ-UN)

Component Cat # Volume
2x MCNextTM SYBR®  Fast qPCR Master Mix (No ROX) SFMM-UN 5mL
10x Primer Mix IQPQ-PX 1 mL
PhiX Library Standard1-100pM IQPQ-PHL1 200 µL
PhiX Library Standard2-10pM IQPQ-PHL2 200 µL
PhiX Library Standard3-1pM IQPQ-PHL3 200 µL
PhiX Library Standard4-0.1pM IQPQ-PHL4 200 µL
PhiX Library Standard5-0.01pM IQPQ-PHL5 200 µL
PhiX Library Standard6-0.001pM IQPQ-PHL6 200 µL
Storage Buffer IQPQ-DSB 3 mL
50x Low ROX IQPQ-RXL 200 µL
50x High ROX IQPQ-RXH 200 µL

MCNext™ SYBR® Fast qPCR Library Quantification Kit (Low ROX) (IQPQ-LR)

Component Cat # Volume
2x MCNextTM SYBR®  Fast qPCR Master Mix (Low ROX) SFMM-LR 5mL
10x Primer Mix IQPQ-PX 1 mL
PhiX Library Standard1-100pM IQPQ-PHL1 200 µL
PhiX Library Standard2-10pM IQPQ-PHL2 200 µL
PhiX Library Standard3-1pM IQPQ-PHL3 200 µL
PhiX Library Standard4-0.1pM IQPQ-PHL4 200 µL
PhiX Library Standard5-0.01pM IQPQ-PHL5 200 µL
PhiX Library Standard6-0.001pM IQPQ-PHL6 200 µL
Storage Buffer IQPQ-DSB 3 mL

MCNext™ SYBR® Fast qPCR Library Quantification Kit (Regular ROX) (IQPQ-RR)

Component Cat # Volume
2x MCNextTM SYBR®  Fast qPCR Master Mix (Regular ROX) SFMM-RR 5mL
10x Primer Mix IQPQ-PX 1 mL
PhiX Library Standard1-100pM IQPQ-PHL1 200 µL
PhiX Library Standard2-10pM IQPQ-PHL2 200 µL
PhiX Library Standard3-1pM IQPQ-PHL3 200 µL
PhiX Library Standard4-0.1pM IQPQ-PHL4 200 µL
PhiX Library Standard5-0.01pM IQPQ-PHL5 200 µL
PhiX Library Standard6-0.001pM IQPQ-PHL6 200 µL
Storage Buffer IQPQ-DSB 3 mL

 

 

Reference Dye Compatible Instruments
No ROX BioRad iCycler MiniOpticon, Opticon 2, Chromo 4, iQ5; Roche LightCycler 480; MJ Re- search DNA Engine Opticon 2,  Chromo 4;  Corbett Rotogene 3000, 6000
Low ROX ABI 7500 qPCR Systems, ViiA 7, QuantStudio 12K Flex, Agilent Mx3000P Mx3005 and Mx4000
Regular ROX ABI PRISM 7000, 7700, 7900HT, ABI 7300 qPCR Systems, GeneAmp 5700, StepOne, and the StepOnePlus

Storage  Condition: -20°C

Shipping Condition: Dry ice

Additional information

OPTIONS

No ROX added, 500 reactions, Regular ROX, 500 reactions, Low ROX, 500 reactions

A

B

Figure 1. Comparison of amplification plot and standard curve of the Illumina PhiX library using MCNext SYBR Fast qPCR Kit (blue) versus KAPA Library Quantification Kit (green). A. Amplification plot of 10 x serial diluted PhiX library. B. 10-fold serial dilution of PhiX library standard curve. Higher fluorescence and 10x better sample quantification range in linear amplification plots confirm that MC kit achieves better efficiency and broader dynamic range.
A

B

Figure 2. Comparison of library quantification consistency using MCNext SYBR Fast qPCR Kit (blue) versus KAPA Library Quantification Kit (green). A. Histograms represent quantification results subtracted by actual Illumina PhiX library concentration (10 nM). B. Standard deviation plot demonstrates superior consistency of MCNext SYBR Fast qPCR Kit (blue) to KAPA Library Quantification Kit (green).
A

B

Figure 3. Analytical result of the Phi X Library Standards. A. Electropherogram from Agilent 2100 Bioanalyzer indicates library average size of 500bp sized aligned with the fragmentation design. B. Melting curve shows a single peak without nonspecific amplification products.